Sand and Dust Test Chamber for Automotive Connectors

Operating Conditions:

Ambient temperature: 5°C~+28°C (average temperature within 24 hours ≤28°C); Ambient humidity: ≤85%

Technical Parameters:

1. Nominal spacing of the metal mesh is 50μm, and the nominal spacing between wires is 70μm

2. Airflow velocity: ≤2m/s (standard type) or ≥2m/s (specify when placing an order) 3. Continuous or periodic dust - blowing can be freely selected, or time can be set 4. Talcum powder dosage: 2kg - 4kg/㎡ 5. Dust for testing: Dry talcum powder, portland cement, soot, etc. 6. Vibration time: adjustable from 0 to 9999 minutes (M represents minutes) 7. Fan cycle time: 0 to 9999 minutes (M represents minutes) 8. Standard configuration: The sand and dust testing equipment is equipped with 2 specimen racks and 2kg of talcum powder 9. Power requirements: AC380(±10%)V/50HZ, three - phase five - wire

Product Applications:

This equipment is suitable for dust - proof and dust - resistance tests of various automotive components, including vehicle lamps, instruments, electrical dust - proof sleeves, steering systems, door locks, etc., to verify the sealing quality of products.

Structural Features:

1. Material of the chamber outer shell: High - quality carbon steel plate, with phosphating and electrostatic powder spraying on the surface, and hairline treatment for SUS304 stainless - steel strips; 2. Inner liner material: Imported SUS stainless - steel polished plate; 3. Chamber door: Tempered glass door, facilitating the observation of the tested samples inside the test chamber; 4. High - quality fixed PU casters are used at the bottom; 5. There is a dust - replacement device at the bottom of the test chamber

System Structure:

1. Control system: The sand and dust testing equipment is controlled by a programmable logic PLC controller to manage the time and sequence of the dust - blowing, vibration and vacuum systems

2. Actuating components: "Schneider" AC contactors, switches, buttons; "Fuji" intermediate relays; "Panasonic" dust - proof sockets

3. Dust pre - heating system: Stainless - steel mica heating jacket, with stable and safe heat; it has timer - controlled heating; Vacuum system: Equipped with a pressure gauge, air filter, pressure - regulating triple unit and connecting pipes (the vacuum pump is provided separately, please specify when placing an order)

4. Power socket for test specimens: Dust - proof socket, AC220V 16A

5. Circulating fan: Low - noise motor with a multi - blade centrifugal impeller

6. Protection system: With protection functions against electric leakage, short - circuit, over - temperature, motor overheating, over - current / power - off memory protection for the controller


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Qinsun 440
Qinsun 440 Standard The Qinsun 440 is engineered to meet stringent international testing standards, including ASTM G155, ISO 105 B02, SAE J2412, and IEC 68...
Automatic Z-axis Vision Measuring Machine
Automatic Z-axis Vision Measuring Machine Product Introduction: The Z-axis automatic image measuring instrument can efficiently detect the wheel corridors and surface shapes of various com...
Five Fingering Scraper
Five Fingering Scraper Standards China: GB/T 2918, GB/T 6151, GB/T 8424.3 Europe: PV3952, BMW GS97034-2, BMW GS97034-9 North America: GMN 3943-2003, FLTM BN 108-13, ...
Water Vapour Permeability Tester
Water Vapour Permeability Tester Information The device is a constant temperature and humidity moisture permeability test device, which is suitable for sportswear and other requ...
Taber Abrasion Resistance Tester
Taber Abrasion Resistance Tester Standards ISO Standards: ISO 9352, ISO 5470, ISO 7784 ASTM Standards: ASTM D1044, ASTM D3884, ASTM D4060 Chinese Standards: GB/T 5137.1, QB/T ...
Все товары поставщика

Похожие товары

Briefly describe the importance, core functionality and how to implement a hospital clock system solution
Briefly describe the importance, core functionality and how to implement a hospital clock system solution Продавец: California Triangle In the healthcare industry, precise time synchronization is critical. Every second can be a matte...
Sand and Dust Test Chamber for Automotive Connectors
Sand and Dust Test Chamber for Automotive Connectors Продавец: Standard International Group (HK) Limited Operating Conditions: Ambient temperature: 5°C~+28°C (average temperature within 24 hour...
Automotive Connector SO₂/H₂S Corrosion Test Chamber
Automotive Connector SO₂/H₂S Corrosion Test Chamber Продавец: Standard International Group (HK) Limited Standards: GB/T 10587-89. GB/T 2423.9-93: Chinese national standards for sulfur dioxide corrosio...
Automotive Connectors Salt Spray Tester
Automotive Connectors Salt Spray Tester Продавец: Standard International Group (HK) Limited Applicable Standards: Neutral Salt Spray (NSS) Tests: GB/T2423.17. ISO 3768/3769/3770. ASTM B117...
Air - tightness Testing Device for Automotive Connectors
Air - tightness Testing Device for Automotive Connectors Продавец: Standard International Group (HK) Limited Main Functions: 1. Provide stable positive and negative pressures for testing the air - tightnes...