Eddy Current Testing Equipment
Specifications: diameter Φ73 / Φ89 mm, length 9.6m or so
Detection speed: 6-20 m / min
Acceptance criteria: American Petroleum Institute API testing standards
The main detection principle of the MFI magnetic flux leakage pipeline inspection method is that the workpiece is magnetized (close to saturation) to have a certain magnetic flux density to generate a leakage magnetic field at the discontinuity, and the magnetic field sensor sends the output signal to the operational amplifier.
Due to the magnetic saturation state, the workpiece has a relatively high magnetic field strength and magnetic field density, and the magnetic lines of force are not limited so that the surface of the workpiece has a large magnetic leakage, which is favorable for on-site detection.
The magnetic sensitive sensor scans along the surface of the magnetized ferromagnetic material, pick up the defect leakage magnetic field and forms a defect electrical signal to achieve the purpose of finding the defect position and parameters.
Non-destructive mfl pipeline inspectiontechnology is widely used in the detection of metal materials and the evaluation of related products due to its fast detection speed, high reliability and low surface cleanliness. Different from magnetic particle detection and detection, the signal in magnetic flux leakage detection is not displayed by magnetic powder, and it has no pollution to the environment: due to various sensitive components (such as Hall element and coil method), the detection result is directly output by electric signal, which is easy to connect with computer to realize digital Processing, so the detection results can be stored and reproduced, facilitating the analysis of the detection signal and the trend analysis of the detection results.
Drill Pipe Magnetic Flux Leakage Detector MFL-308 Performance
Drill pipe inspection method |
Drill pipe straight ahead, test assembly fixed |
Detection range |
F60-F168drill pipe |
transport system speed |
6-20m/min;variable frequency range |
Testing methods |
Automatic charging, Automatic testing, Automatic sorting |
The sensitivity of hole detection |
|
Accuracy of section area measurement |
2-4% |
Position resolution accuracy |
20mm |
Non-detection zone |
£100mm(drill pipe body) |
False alarm rate |
£0.5% |
Remaining magnetism after demagnetization |
£10GS |
The internal and external surface coverage |
100% |
Equipment usage environment |
Working temperature:40°-minus50°; Working humidity:0-95%; |
Nanjing BOKENA Automation System Co., Ltd., originated from the eddy current testing laboratory of the Nanjing University of Technology. It isone of the most professional ndt testing equipment suppliersin China. We sincerely invite and welcome people from all around the world to invest and create more values together.
在线联系供应商
Other supplier products
RQ-120-B Automatic CNC EDM Notch | "RQ-120-B Electric Pulse Automatic CNC EDM notches" is a precise instrument specially developed by Nanjing BKN Automation System Co., Ltd. for maki... | |
Magnetic Flux Leakage Testing Equipment | Electromagnetic detection is a very important non-destructive testing method and is widely used. Magnetic flux leakage is a magnetic method of nond... | |
Connecting rod hardness eddy current sorting machine LGYDFX-01 | The connecting rod hardness eddy current sorting machinehas a calibration device, input compensation parameters, automatic/manual temperature compe... | |
Eddy Current Testing Equipment | ECT Eddy current testing used by eddy current test setis a non-contact testing method, which mainly uses the electromagnetic field and electromagne... | |
Drill Pipe Magnetic Flux Leakage Detector MFL-308 | Specifications: diameter Φ73 / Φ89 mm, length 9.6m or so Detection speed: 6-20 m / min Acceptance criteria: American Petroleum Institute ... |