Hydraulic Oil Precision Filter Tester
1.Conformity standard:
GJB420. NAS1638. ISO4406. 18/16/13
2.Characteristics and Applications
2.1 Features of oil filter:
● Specialized gear pump set with low noise, strong self-priming ability and smooth operation.
● The high pressure pipeline is equipped with overflow protection device, which can effectively protect the safety of the hydraulic system.
● The coarse filter at the suction port protects the oil pump and extends the service life of the main filter.
● The fine filter can be selected with different precision according to the different needs of users to achieve the required results.
● The panel is equipped with a pressure gauge, which continuously indicates the operating condition of the system and the degree of contamination of the filter element during operation. There are differential pressure transmitters on the pre-filter and fine filter to indicate the system cartridge at any time.
2.2 Application of oil filtering machine:
Filtration of hydraulic lubrication system during refueling.
● Bypass filtration of hydraulic lubrication system during operation.
● Circulation filtration of hydraulic lubrication system before operation.
● Hydraulic lubrication system oil is not filtered and pumped out by the pump of the equipment itself.
(Note: This machine is not applicable to flammable and explosive media such as fuel oil.)
3. Technical Parameters:
Working Pressure: 0.6MPa
Differential Pressure for Alarm: 0.2MPa
Flow Rate: 50±5L/min
Medium: ≤160mm/s (20℃)
Accuracy: 5μm
Rated Power: 2.2KW
Power Supply Voltage: 3-phase 380V
Frequency: 50Hz
Operating temperature: 20 ℃ - 70 ℃
4. Cleaning and replacement of the filter:
When the oil filter works for a period of time, the oil filter oil system pressure increases accordingly, the performance of its components have different effects, especially on the filter precision of the filter element of the shadow
core damage, the main reason for this is that the filter element of the differential pressure rises, the need to replace the filter element. Specific cleaning and replacement methods are as follows:
4.1 Cleaning: (only on the pump before the suction oil filter)
4.1.1 Cleaning cycle: oil filter continuous work for a week (about 150 hours)
a. Unscrew the top cover of the oil suction filter and take out the filter element.
b.Cleaning the filter element:When cleaning the filter element, soak it with gasoline for about half an hour and then remove the impurities with a brush.
4.2 Replacement
4.2.1. Conditions for replacement: When the oil filter is filtering, when the red indicator pops up on the differential pressure alarm installed on the pre-filter and fine filter, the cartridge needs to be
4.2.2 Replacement method: loosen the four bolts on the upper cover of the pre-filter and fine filter, remove the upper cover, take out and replace the filter element.
5.Precautions
5.1 The oil filter can not filter gasoline and other flammable liquids.
5.2 If the oil pool (or tank) of the oil is too dirty and there may be large obstacles, in the suction port should be installed on the large mesh filter protection.
5.3 The oil suction and discharge pipes should be kept clean.
在线联系供应商
Other supplier products
| Xenon Lamp Aging Testing Machine for Helmets | Xenon Lamp Aging Testing Machine for Helmets - Other test instrument - standard Standards: ISO 4892 - 2, ASTM G155, GB/T 16422, etc. Appli... | |
| Liquid Spontaneous ignition point tester | Product Description complies with GB/T 21860-2008 “Test Method for Autoignition Temperature of Liquid Chemicals” and ASTM E “Tes... | |
| Gelbo Flex flexing chamber ISO 9073.10 YY/T 5056.6 | Standards YY/T 5056.6 Surgical drapes, gowns and clean air suits, used as medical devices for patients, clinical staff and equipment - Part 4: Dry... | |
| Veslic Multi-Functional Material Tester for Advanced Quality Control | Standard ISO 13934-1(Tensile Properties of Fabrics) ASTM D624(Tear Strength of Rubber and Elastomers) AATCC 135(Dimensional Changes in Textiles ... | |
| Bone Plates Static Four Point Bending Tester | Standard YY/T 0342-2022: Chinese standard specifying methods for determining bending strength and equivalent bending stiffness of straight and p... |
Same products
| KL‑016A Benchtop High‑precision pH Meter | 卖方: 科立龙电子股份有限公司ctron Co.Ltd | Product Description: Large‑screen display with high resolution and precision for con... | |
| Large Naïve VHH Library | 卖方: AlpVHHs | Large Naïve VHH Library VHHare single-domain antibodies derived from the variable regions o... | |
| PH-2398 pH/EC/ORP/温度 多参数测试仪 | 卖方: 科立龙电子股份有限公司 | 大显示,可同时进行水质PH、氧化还原电位、电导率、温度的测量; 带背光LCD显示清晰,功能齐全,精度高; 仪表采用微电脑测量与控制技术,具有自动校准功能,方便实用。 内置蓝牙,可以与电脑或... | |
| ORP-2026S 防水型 土壤ORP&温度 二合一测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| 防水型 EC /TDS/温度三合一参数测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 EC ~19.9mS TDS Temp 0~50℃ 分辨率 ... |