Building material flame retardancy test furnace,building code compliance equipment
Technical parameters:
Gas used: methane flow rate (35 ± 0.5)L/min, its purity is greater than 95%, air flow rate (17±0.2)L/min
Specimen size: Each test takes 4 specimens as a group
Thermocouple: nickel-chromium-nickel-silicon thermocouple with a wire diameter of 0.5mm and an outer diameter not greater than 3mm
Furnace wall temperature: Room temperature ——100°C ——1 °C
Intake temperature: 0——50±0.5°C
Pressure difference: 0——30Pa±1Pa
Pressure difference measurement range: 0-100pa, accuracy :0.2%
Temperature recorder and thermostat: multi-channel continuous temperature recording and curve display
Constant temperature: (23±2)°C
Constant current: (10+1)m3/min
Ambient temperature: 19——30°C
Power supply: 380VAC 50HZ
Dimensions of combustion shaft furnace: 1020mmx1020mmx3930mm
Internal size of combustion shaft furnace: 800mmx800mmx2000mm
在线联系供应商
Other supplier products
| Film impact Tester (Gardner) | The Film Impact Tester (Gardner) is designed to evaluate the impact resistance of coatings and paint films. It determines the degree of damage such... | |
| Fiber Blend Ratio Tester | The Fiber Blend Ratio Tester is designed to measure the electrical resistance of a compacted fiber sample and convert it into the specific resistan... | |
| Bubble Leak Tester | The Bubble Leak Tester utilizes a positive pressure testing principle and is suitable for the quantitative measurement of sealing strength, heat se... | |
| Automatic Reaction Calorimeter | This instrument is a professional testing instrument that simulates the specific process of chemical reactions on a liter scale, and measures and c... | |
| Vertical low temperature cold resistance meter | Product description: This machine is used to test finished shoes, rubber, plastic, soles, synthetic leather and other cold resistance degree to un... |