Building Material Radiant Panel Test Machine,AS/NZS 1530.3

Products

This machine is designed according to AS/NZS 1530.3;

Thedeviceviaagasradiantplatetoheatsamplesandwithheatflowmetertocalibration;Testsampleswere placed inaverticalposition, neartheradiationplate,exposedinaclearareacalibratedradiationflux. Closetothepilotflame isassembled withtestsample, but not in contact withthetestsample.

After ignition, to record the ignition time, flame propagation time, heat release integral, Smoke Release etc.

Standard

AS/NZS 1530.3

Feature

1.All structural components are made of stainless steel, nice appearance, corrosion resistance;

2.Sample fixture could be movable to adjust the distance to radiant panel.

3.Ignition sources: radiation plate and two pilot flame burners;

4.One pilot flame burner is fixed before the sample at 15mm

from front face of sample and 50mm above the centre of the samples. And the other burner could be moved before the sample.

5.Flame height is controlled by imported flow control meter.

6 , Samples size: 710mm x610mm;

7.Stainlesssteelhoodandfluetocollectthesmokeofspeciments. Hoodsize: 1140mmx1140mm;smoketubeis

dia.305mm;

8 , Radiant panel size:300mmx300mm; Withporousfire-brick surface.

9.Radiationplatetemperatureprobe: preventflamesturnedtheheatradiatingplaterearside;

10. Precise gas and air flow control to realized the radiant panel heatadjustment.

11. ProvideHeatfluxsenorfixturetocalibratetheradiationlevelaccordingtostandardrequest2.4kw/;

12. Two shield could be removed as standardrequest.

13. 19 rack to measure the flame spread rate analysis, critical flow, heat releaserate

14. Provide an exhaustfan.

Optical system

1. The optical system comprising a light source color temperature is 2900 ± 100 K incandescent, light receiving silicon photodiode with an optical path test shutter, 0% and 100%, to facilitate the use of calibration;

2. Imported light battery module measuring light attenuation. The system automatically calculates and generates a light transmittance curve translucent; printable Scribble

3. One button automatic and five level (0.25%,50%,75%,100%)calibration system by computer.

Test System

1.TheUnitedStates importedMethermthermopiletypeheatflowmeter-Designrange0^10kW/m²,the accuracy of heat flow meter is±3%, repeatability is ±0.5%.

2. Gas supply: with a valve, zero-pressure valve, tempering valves, solenoid valves and a mixer, the mixed air and fuel gas supplied to the radiation plate.

3. All radiant panel combustion control system safety explosion-proof, check valve, cut off the gas solenoid valve prevents the gas reflux

4 , The camera can observe a situationandsave thetest program (Optional)

5. Dataacquisitionsystem canstorethedataofignitiontime,flamepropagationtime,heatreleaseintegral,

smoke release etc.

6 , Radiation plate burner system is fully automated, with spark ignition and safety protect system;

7 , Labviewcontrol system,user-friendly, easytooperate, precise control;

8. Signalacquisitionandprocessingmoduleandtheairvolumecontrolmodulecircuitlinkedbyaprogrammable

logic controller;

9 , 10kV spark ignition, with safety cease-fire devices.

10. Automatic ignition system; Automatic timing; Expire automatically turn off;

11 , Window + Labview system torealize automatictestsysterm

12. Equippedwithaudiblealarmandalarmdisplayfunctionsaccidents.

13. The control box USB / RS232 serial port, external desktop / notebook computer operation control, free to

print the test report.

14. Automatic smoke density calibration system.

Specification

Pover:AC220V±10% , 50Hz;5KW;

Size:Test stand(Length1.4× width1.0× High2.2 )m;Control box: 600(W)×750(D)×1600(H)mm

Weigth:350Kg.

Remarks: As the standard request hood and flue about 3270mm high and above ground 4000mm; So customer will be responsible for the hood and flue assemble based on TESTech's engineering instruction to save customer's cost.

Testech will provide the flue length according to standard request 3270mm and one separate exhaust fan for system control. And customer will be responsible for the additional flue material and install.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Bone Cement Four-Point Bending Fatigue Tester
Bone Cement Four-Point Bending Fatigue Tester Standard YY/T 1429 (China): Specifies four-point bending fatigue tests for acrylic resin bone cements under quasi-static and cyclic loading. ISO ...
Mechanical load testing machine for photovoltaic modules
Mechanical load testing machine for photovoltaic modules Standard IEC 61215: Terrestrial Photovoltaic (PV) Modules – Design Qualification and Type Approval IEC 61646: Thin-Film Terrestrial Photo...
Battery Test Chamber丨Battery Test mechine
Battery Test Chamber丨Battery Test mechine Features and Benefits 1.Wide temperature range (-70℃ to +150℃),temperaturefluctuation ≤±0.5℃, Humidity control accuracy±2%RH,th...
Catheter Power Injection Flow and Pressure Tester
Catheter Power Injection Flow and Pressure Tester Main Uses The catheter flow and pressure tester for power injection is an important medical device, mainly used to detect key parameters such as f...
Bottle Wall and Bottom Thickness Tester
Bottle Wall and Bottom Thickness Tester The wall and bottom thickness tester for bottles is a measuring instrument widely used in the pharmaceutical, food, cosmetics, and other industries...
供应产品

Same products

Test for Flammability of Materials ,AS1530.2,Fire reaction test apparatus
Test for Flammability of Materials ,AS1530.2,Fire reaction test apparatus 卖方: Standard International Group (HK) Limited Introduction Thistester is developed base on thestandard AS1530.2. test for flammability of mate...
Building Material Radiant Panel Test Machine,AS/NZS 1530.3
Building Material Radiant Panel Test Machine,AS/NZS 1530.3 卖方: Standard International Group (HK) Limited Products This machine is designed according to AS/NZS 1530.3; Thedeviceviaagasradiantplatetohea...
Radiant Panel Flame Spread Apparatus,fire spread test machine
Radiant Panel Flame Spread Apparatus,fire spread test machine 卖方: Standard International Group (HK) Limited Description ASTM E162 is one most widely used test standard to evaluate the propagation properti...
Single-Flame Source Tester, ISO11925-2,DIN 53438;  DIN4102-1
Single-Flame Source Tester, ISO11925-2,DIN 53438; DIN4102-1 卖方: Standard International Group (HK) Limited Introduction This instrument is designed according to ISO11925-2. it is used to test building ma...
Density of Smoke from the Burning or Decomposition of Plastics,ASTM D2843 Smoke Density Test
Density of Smoke from the Burning or Decomposition of Plastics,ASTM D2843 Smoke Density Test 卖方: Standard International Group (HK) Limited Introduction In a fire, people are often smoke suffocated or unable to escape because of the inv...