Building Material Radiant Panel Test Machine,AS/NZS 1530.3
Products
This machine is designed according to AS/NZS 1530.3;
Thedeviceviaagasradiantplatetoheatsamplesandwithheatflowmetertocalibration;Testsampleswere placed inaverticalposition, neartheradiationplate,exposedinaclearareacalibratedradiationflux. Closetothepilotflame isassembled withtestsample, but not in contact withthetestsample.
After ignition, to record the ignition time, flame propagation time, heat release integral, Smoke Release etc.
Standard
AS/NZS 1530.3
Feature
1.All structural components are made of stainless steel, nice appearance, corrosion resistance;
2.Sample fixture could be movable to adjust the distance to radiant panel.
3.Ignition sources: radiation plate and two pilot flame burners;
4.One pilot flame burner is fixed before the sample at 15mm
from front face of sample and 50mm above the centre of the samples. And the other burner could be moved before the sample.
5.Flame height is controlled by imported flow control meter.
6 , Samples size: 710mm x610mm;
7.Stainlesssteelhoodandfluetocollectthesmokeofspeciments. Hoodsize: 1140mmx1140mm;smoketubeis
dia.305mm;
8 , Radiant panel size:300mmx300mm; Withporousfire-brick surface.
9.Radiationplatetemperatureprobe: preventflamesturnedtheheatradiatingplaterearside;
10. Precise gas and air flow control to realized the radiant panel heatadjustment.
11. ProvideHeatfluxsenorfixturetocalibratetheradiationlevelaccordingtostandardrequest2.4kw/;
12. Two shield could be removed as standardrequest.
13. 19 rack to measure the flame spread rate analysis, critical flow, heat releaserate
14. Provide an exhaustfan.
Optical system
1. The optical system comprising a light source color temperature is 2900 ± 100 K incandescent, light receiving silicon photodiode with an optical path test shutter, 0% and 100%, to facilitate the use of calibration;
2. Imported light battery module measuring light attenuation. The system automatically calculates and generates a light transmittance curve translucent; printable Scribble
3. One button automatic and five level (0.25%,50%,75%,100%)calibration system by computer.
Test System
1.TheUnitedStates importedMethermthermopiletypeheatflowmeter-Designrange0^10kW/m²,the accuracy of heat flow meter is±3%, repeatability is ±0.5%.
2. Gas supply: with a valve, zero-pressure valve, tempering valves, solenoid valves and a mixer, the mixed air and fuel gas supplied to the radiation plate.
3. All radiant panel combustion control system safety explosion-proof, check valve, cut off the gas solenoid valve prevents the gas reflux
4 , The camera can observe a situationandsave thetest program (Optional)
5. Dataacquisitionsystem canstorethedataofignitiontime,flamepropagationtime,heatreleaseintegral,
smoke release etc.
6 , Radiation plate burner system is fully automated, with spark ignition and safety protect system;
7 , Labviewcontrol system,user-friendly, easytooperate, precise control;
8. Signalacquisitionandprocessingmoduleandtheairvolumecontrolmodulecircuitlinkedbyaprogrammable
logic controller;
9 , 10kV spark ignition, with safety cease-fire devices.
10. Automatic ignition system; Automatic timing; Expire automatically turn off;
11 , Window + Labview system torealize automatictestsysterm
12. Equippedwithaudiblealarmandalarmdisplayfunctionsaccidents.
13. The control box USB / RS232 serial port, external desktop / notebook computer operation control, free to
print the test report.
14. Automatic smoke density calibration system.
Specification
Pover:AC220V±10% , 50Hz;5KW;
Size:Test stand(Length1.4× width1.0× High2.2 )m;Control box: 600(W)×750(D)×1600(H)mm
Weigth:350Kg.
Remarks: As the standard request hood and flue about 3270mm high and above ground 4000mm; So customer will be responsible for the hood and flue assemble based on TESTech's engineering instruction to save customer's cost.
Testech will provide the flue length according to standard request 3270mm and one separate exhaust fan for system control. And customer will be responsible for the additional flue material and install.
在线联系供应商
Other supplier products
| Cleanliness automatic extractor | Component Cleanliness Cabinet equipped with cleaning modes such as pressure jet cleaning, perfusion cleaning, spray cleaning, etc., the cleaning ag... | |
| Protective Clothing Synthetic Blood Penetration Tester | Introduction It is applicable to the resistance of the protective clothing to the synthetic blood penetration under different levels of test press... | |
| Micro Controll Constant-Speed Friction Plate Tester | Standards GB5763-1998 brake linings for automobiles; GB/T5764-1998 brake linings for automobiles; GB/T5764-1998 brake linings for automobiles. ... | |
| Wet Microbial Penetration Tester | The wet microbial penetration tester is mainly used to evaluate the barrier ability of medical protective equipment (such as surgical gowns, isolat... | |
| Aluminum Tube Internal Coating Continuity Tester | The Aluminum Tube Internal Coating Continuity Tester is an important device specifically designed for testing the continuity of the internal coatin... |
Same products
| Full-Body Garment Stress Tester,FZ/T 70015 | 卖方: Standard International Group (HK) Limited | TheFull-Body Garment Stress Testeris a precision instrument designed to quantify the pressure exe... | |
| Industrial Dry Cleaning Machine,industrial garment steamer | 卖方: Standard International Group (HK) Limited | TheIndustrial Dry Cleaning and Energy-Saving Dryer Machinesare designed for high-performance, rel... | |
| MST Medical Compression Stocking Tester,compression sock tester | 卖方: Standard International Group (HK) Limited | The MST Medical Compression Stocking Tester is a professional instrument designed to evaluate the... | |
| MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool | 卖方: Standard International Group (HK) Limited | Applications Textile Manufacturing:Testing waterproof fabrics for outdoor gear R&D:Developi... | |
| Dental material color stability tester | 卖方: Standard International Group (HK) Limited | Application The applications of color stability testers for dental materials are mainly reflecte... |