Automatic Cleveland Open-Cup Flash Tester FDT-0131

Fully automatic closed flash point tester cryogenic FDT-0233Application range
Conforms to standard GB/T261-83 and ISO2719-1988 ASTM D93 standard requirements.Features
1, color LCD touch-screen operator interface is friendly
2, the instrument also has a failure since Jane functionality, failure automatically prompt function
3, the instrument has to heat up automatic control, automatically opening the lid and ignition, automatic printout, automatic cooling, the machine automatically complete the barometric pressure correction and automatically display the flash point temperature, built-in micro-thermal printer automatically report the test results
The 4, USB/232 communications interface to communicate with the host computer, easy to form a centralized management system
5, German imports of stainless steel temperature sensor detects the temperature data is accurate and reliable
Mechanical moving parts servo drive timing belt drive, work without gaps, low noise, reliable and difficult to damage, no lubrication maintenance.
7, simply set the expected flash point instrument in strict accordance with the standard automatic test, the end of the test automatically print test results, and tone.Without judgment and does not depend on the proficiency of the operator.
8, thermocouple detection flash point of high sensitivity detection of accurate, durable and easy to maintain.
9, sample box the thermal compound thermostat with built-in refrigeration heating and German imports Dan whisk Adams compressor, thermostat reliable lag, not easily damagedSpecifications
1, use environment: Temperature 0 ~ 60° C; Relative humidity: ≤ 80%
2: 7-inch color LCD touch screen.
3, the heating rate: less than 50 ° C; 1° C; / min, higher than 50 ° C; for 2-3 ° C; / min
4, the temperature range: -30 to +80° C Accuracy ± 1° C;
5,Temperature components: PT100 stainless steel temperature sensor
6, the lifting arm: automatically raised or lowered
7, ignition: gas flame ignition
8, detection: automatically detects flash fire and automatically print the experimental data.
9, Communication: USB/232, communication interface.
10, the cooling system: compressor cooling
11 Print: You can print this or any print stored 100 experimental results
12, using the power AC220V 50Hz, total power: 1.5 kw
Other supplier products
|
|
Automatic Cooled Cold-Cranking Simulators |
Application range
Automatic Cooled Cold-Cranking Simulators applicable standards: GB/T6538 ASTM D5293, The instrument is mainly test cryogenic eng... |
|
|
Grease copper strip corrosion tester FDH-4001 |
Application range
Grease copper strip corrosion tester applicable standards: GB/T7326
Features
Grease copper strip corrosion tester with integra... |
|
|
oil density Tester FDT-1531 |
Application range
Applicable in accordance with the standard GB/T6536-1997,Petroleum products - Determination of distillation,Regulations as wel... |
|
|
Grease Similar viscometer FDH-4301 |
Application range
The grease drum Stability tester applicable standards ASTM D1831 SH/T0122
Measured with a certain amount of the sample, to ... |
|
|
oil density Tester FDT-1531 |
Application range
Mechanical impurities of petroleum products and additives analyzer is designed in accordance with the national standards GB/... |
供应产品