Photovoltaic module damp heat test chamber
The Photovoltaic Module Damp Heat Test Chamber is designed to simulate long-term tropical aging conditions for photovoltaic modules and related electronics. By combining high temperature and high humidity control, the system enables accelerated evaluation of module reliability, encapsulant degradation, and potential PID (Potential Induced Degradation) effects. It is suitable for R&D laboratories, quality assurance, and certification testing in compliance with international standards.
Application
Accelerated aging tests of photovoltaic modules under high temperature and humidity.
Evaluation of PID resistance and encapsulant performance.
Reliability testing of batteries, PV modules, and electronic assemblies in wet and humid conditions.
Indoor certification and R&D testing for IEC/UL compliance.
Standards
IEC 61215: Terrestrial Photovoltaic (PV) Modules – Design Qualification and Type Approval
UL 1073: Standard for Safety for Enclosures for Electrical Equipment
ISO 16750-4: Road Vehicles – Environmental Conditions and Testing for Electrical and Electronic Equipment
CE Certification (Conformité Européenne)
Features
Extreme Environmental Simulation: 85°C ±2°C / 85% RH control replicates 10+ years of tropical aging in 1,000 hours.
Ultra-Stable Performance: ±1°C temperature stability and ≤2°C uniformity for consistent long-term testing.
Energy Efficiency: Advanced insulation and heat recovery reduce power consumption by 40%; ECO mode for auto power-down during stabilization.
Safety First: Dual overload protection with thermal cutout and door interlock system.
Smart Diagnostics: AI-powered degradation prediction using IV curve shifts and EL imaging data; remote monitoring via 4G/LTE.
Flexible Operation: Dual-chamber design enables simultaneous wet/dry testing; modular expansion up to 1,500 L for full-size PV arrays.
User-Friendly Interface: 10” touchscreen HMI with preloaded IEC/UL test profiles and automated condensation drainage.
Glovebox Compatibility: Oxygen/moisture controlled operation for sensitive electronics.
Parameters
| Parameter | Specification |
|---|---|
| Temperature Range | 30°C to 85°C (operational) |
| Temperature Stability | ±1°C (at 85°C setpoint) |
| Temperature Uniformity | ≤±2°C (empty chamber) |
| Humidity Range | 30%–95% RH (non-condensing) |
| Humidity Stability | ±2.5% RH (at 85% RH) |
| Chamber Volume | 500 L (standard), expandable to 1,500 L |
| Power Supply | 380V/415V, 3-phase, 50/60Hz |
| Dimensions (W×D×H) | 1,200 mm × 1,800 mm × 2,000 mm |
| Weight | 800 kg (net) / 1,200 kg (gross) |
Accessories
Testing Kit: 4x universal sample racks (adjustable for batteries/PV modules/PCBAs), 10x humidity sensor calibration capsules
Software Suite: License key for EnviroTest Pro (Windows/Linux), 1-year free access to cloud-based test report generator
Calibration & Safety: NIST-traceable temperature/humidity logger, emergency eyewash station (portable)
Maintenance Kit: Spare heating elements and refrigerant filters, chamber cleaning solution (non-corrosive)
Documentation: Multilingual quick-start guide (printed + digital)
Test Procedures
Install test samples securely on the sample racks.
Set desired temperature and humidity profile using the touchscreen HMI.
Initiate the test cycle and monitor chamber conditions.
Record environmental data and any module performance changes throughout the test.
Complete the test and perform post-test inspection of modules or assemblies.
Export test reports for analysis or certification documentation.
Maintenance Information
Inspect heating elements, humidity sensors, and chamber seals regularly.
Clean interior surfaces and drainage channels to prevent mold or corrosion.
Verify calibration of temperature and humidity sensors periodically with NIST-traceable standards.
Replace worn or degraded components (heating elements, filters) according to operational hours.
Ensure safety interlocks and emergency systems are functional before operation.
在线联系供应商
Other supplier products
| Intramedullary Nails Static Four-point Bending Tester | Standard YY/T 0591 (China): Standard for static four-point bending tests of lockable intramedullary nails. ASTM F1264 (International): Specificat... | |
| Precision Fiber Slicer | introduction G214Precision Fiber Slicer is used to make the accurate fiber cross-sectional specimens for further inspection or research under the ... | |
| Automatic Cleanliness Extractor | Component Cleanliness Cabinet equipped with cleaning modes such as pressure jet cleaning, perfusion cleaning, spray cleaning, etc., the cleaning ag... | |
| Adiabatic Self - Accelerating Decomposition Temperature Tester | Product Introduction This product complies with "Recommendations on the Transport of Dangerous Goods - Manual of Tests and Criteria" 28.4.2 Test H... | |
| DSC Differential Scanning Calorimeter | The Differential Scanning Calorimeter (DSC) measures heat flow to/from a sample (1-10 mg) in a closed crucible within a temperature-controlled furn... |
Same products
| Air Permeability Tester STD- F8 | 卖方: Standard International Group (HK) Limited | The Air Permeability Tester is designed to quickly and accurately measure the breathability and p... | |
| Surface Performance Tester STD-FB4 - A | 卖方: Standard International Group (HK) Limited | Introduction TheSurface Tester analyzes finger movements-particularly, strokes-performed by arti... | |
| Compression Tester STD - FB3 - A | 卖方: Standard International Group (HK) Limited | TheCompression Tester analyzes hand movements-particularly, pushing with a finger-performed by ar... | |
| Single - Strand Bending Tester STD - FB2 - SH | 卖方: Standard International Group (HK) Limited | Standards ASTM A370. ASTM A416. ISO6934.4 The Single Fiber Bending Tester makes it possible to ... | |
| Bending Tester STD- FB2 - S | 卖方: Standard International Group (HK) Limited | Compliance Standards ASTM D790 (Plastics Flexural Properties) ISO 178 (Flexural Strength of Rig... |